W-5600 Base Plating System

  • Fully automated, computer controlled Base Plating System
  • S&A 250B Network Analyzer Monitor Crystal Measurement System
  • Quartz monitor crystal rotates on the same spherical radius as devices being plated for accurate plating control
    (Patent No. 6,090,444)
  • Each mask can be plated to a different thickness in the same deposition cycle
  • Mechanical assemblies shielded from plating material and easily removed for cleaning
  • Low profile bell jar assembly for easy operator access
  • Supports various mask systems
  • Substrate heater
  • RF plasma bombard
  • Plating units: Å, Hz, F2, Å of Si 02
Specifications
Plating Uniformity: 2% of plateback typical *

* Performance based on mask dimensions of not greater than 3 x 4.2″.

System Configuration
  • Direct Drive Roughing Pump
  • Cryo or Diffusion Pump
  • Automatic Mask Flipping Mechanism
  • Two Metal, 3 Layer Capability
  • Substrate Heater
  • S&A 250B Network Analyzer
  • Plasma Cleaning
  • Light Pole
  • Computer Requirements:
    • Windows® based System Software
  • Printer (optional)
Facility Requirements
Power: 380V or 208V 3-PHASE, 7 KVA, 50/60 Hz
Inlet Pressure (Air): 90 – 100 PSIG
Inlet Pressure (Nitrogen): 70 – 100 PSIG
Inlet Pressure (Argon/Oxygen 80/20 – plasma cleaning): 10 PSIG
Cryo Pump Water Cooling: 0.50 GPM @ 60° – 80°F
Diffusion Pump Water Cooling: 0.25 GPM @ 60° – 80°F
Dimensions: W 53 x D 34 x H 67.5 Inches
(excluding Cryo Compressor)

The Roditi International Corporation Ltd is the exclusive European representative of Saunders & Associates, LLC